T. Goldbrunner et al., NEUTRON-ACTIVATION ANALYSIS OF DETECTOR COMPONENTS FOR THE SOLAR-NEUTRINO EXPERIMENT BOREXINO, Journal of radioanalytical and nuclear chemistry, 216(2), 1997, pp. 293-297
The proposed solar neutrino experiment BOREXINO requires detector comp
onents of high radiopurity. The acceptable levels for U and Th contami
nations reach down to the sub-ppq region. To select suitable materials
a very sensitive analysis method have to be applied. In this article
a highly developed neutron activation analysis techniques are presente
d, which have been used to determine the K, Th and U content of detect
or components, namely nylon, water and liquid scintillator.