STUDY OF THE UNDULATOR SPECIFICATION FOR THE VUV-FEL AT THE TESLA TEST FACILITY

Citation
B. Faatz et al., STUDY OF THE UNDULATOR SPECIFICATION FOR THE VUV-FEL AT THE TESLA TEST FACILITY, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 393(1-3), 1997, pp. 380-384
Citations number
14
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
393
Issue
1-3
Year of publication
1997
Pages
380 - 384
Database
ISI
SICI code
0168-9002(1997)393:1-3<380:SOTUSF>2.0.ZU;2-X
Abstract
In this paper, the influence of undulator errors, more specific magnet ic held errors, on the Free-Electron Laser performance is investigated . Both the influence of variation in undulator peak field and of dipol e fields resulting from misaligned quadrupoles, is considered. For the se quantities, upper limits are given, and the influence of additional correction stations on the reduction in performance is studied.