EXPERIMENTAL CHARACTERIZATION OF CANDELA PHOTO-INJECTOR

Citation
C. Travier et al., EXPERIMENTAL CHARACTERIZATION OF CANDELA PHOTO-INJECTOR, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 393(1-3), 1997, pp. 451-454
Citations number
12
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
393
Issue
1-3
Year of publication
1997
Pages
451 - 454
Database
ISI
SICI code
0168-9002(1997)393:1-3<451:ECOCP>2.0.ZU;2-1
Abstract
CANDELA photo-injector is made of a 2-cell S-band RF gun, using a disp enser cathode illuminated by a Ti:sapphire laser. This electron source provides a single bunch (at 12.5 Hz), with a charge of 1 nC and an en ergy of 2MeV. After recalling the experimental set-up, this paper pres ents some results concerning mainly energy and bunch length measuremen ts and also comparisons with simulations done with the PARMELA code. M easured pulse durations of less than 10 ps show for the first time tha t dispenser photocathodes are ''fast response'' cathodes.