COHERENT TRANSITION RADIATION DIAGNOSTIC FOR ELECTRON BUNCH SHAPE MEASUREMENT AT FELIX

Citation
Ms. Ding et al., COHERENT TRANSITION RADIATION DIAGNOSTIC FOR ELECTRON BUNCH SHAPE MEASUREMENT AT FELIX, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 393(1-3), 1997, pp. 504-509
Citations number
10
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
393
Issue
1-3
Year of publication
1997
Pages
504 - 509
Database
ISI
SICI code
0168-9002(1997)393:1-3<504:CTRDFE>2.0.ZU;2-A
Abstract
An optical autocorrelation system using coherent transition radiation has been set up to determine the electron bunch shape at FELIX. A pola risation interferometer and a 10 x 10 mm(2) pyroelectric detector are used to allow operation over a wide range of wavelength (from 30 mu m to 10 mm) without strong variation in efficiency. An evacuated 15 m lo ng overmoded waveguide is used to transport the transition radiation t o the experimental area. The intensity of the transition radiation was measured and compared with our calculation. The phase-retrieval techn ique applied to the measured spectrum provides details of the electron bunch. The bunch shapes have been studied at different buncher phase settings. Measurements of coherent transition radiation and coherent u ndulator radiation are compared.