PERFORMANCES OF A PULSATING COLUMN FOR LIQUID-LIQUID-EXTRACTION

Citation
Rz. Tudose et al., PERFORMANCES OF A PULSATING COLUMN FOR LIQUID-LIQUID-EXTRACTION, Hungarian journal of industrial chemistry, 25(3), 1997, pp. 203-208
Citations number
17
Categorie Soggetti
Engineering, Chemical",Chemistry
ISSN journal
01330276
Volume
25
Issue
3
Year of publication
1997
Pages
203 - 208
Database
ISI
SICI code
0133-0276(1997)25:3<203:POAPCF>2.0.ZU;2-1
Abstract
This paper presents the experimental results obtained to establish the performances of a pulsating column for liquid-liquid extraction with sieve plates and a new type of pulsation generator. The effects of amp litude and frequency of pulsation and of the distance between two cons ecutive plates on hold-up, volumetric efficiency and height equivalent to a theoretical plate for mass transfer are investigated. The data s how that it can be included in the group of extractors of the highest performance.