ON THE SIGNIFICANCE OF ELECTRICAL DAMPING IN TORSION BALANCE

Authors
Citation
Zb. Zhou et J. Luo, ON THE SIGNIFICANCE OF ELECTRICAL DAMPING IN TORSION BALANCE, Chinese Physics Letters, 14(8), 1997, pp. 565-568
Citations number
4
Categorie Soggetti
Physics
Journal title
ISSN journal
0256307X
Volume
14
Issue
8
Year of publication
1997
Pages
565 - 568
Database
ISI
SICI code
0256-307X(1997)14:8<565:OTSOED>2.0.ZU;2-F
Abstract
A typical electrical damping circuit for increasing the damping coeffi cient of a torsion balance system in high vacuum is discussed in detai l. Theoretical analysis and numerical estimation performed with typica l experimental parameters show that the signal-noise ratio can be impr oved by partial cooling of the electrical damping circuit. This is sig nificant for the torsion balance experiments.