LOW MAGNETIC-FIELD MEASUREMENT BY A SEPARATED NMR DETECTOR USING FLOWING WATER

Citation
Bc. Woo et al., LOW MAGNETIC-FIELD MEASUREMENT BY A SEPARATED NMR DETECTOR USING FLOWING WATER, IEEE transactions on magnetics, 33(5), 1997, pp. 4345-4348
Citations number
7
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
00189464
Volume
33
Issue
5
Year of publication
1997
Part
3
Pages
4345 - 4348
Database
ISI
SICI code
0018-9464(1997)33:5<4345:LMMBAS>2.0.ZU;2-5
Abstract
Using polarized flowing water, NMR detection at a high field region se parated far away from the measured field was investigated to estimate ranges and conditions for a wide-range magnetometer. We obtained the L orentzian-type NMR signal with the full-half-maximum width of 320 nT a nd the S/N ratio of 10.5, and measured the magnetic field from several mT down to a few mu T with the same enhancement of signals by a separ ated NMR detector.