ANALYSIS OF PMLSM USING 3-DIMENSIONAL EQUIVALENT MAGNETIC-CIRCUIT NETWORK METHOD

Citation
J. Hur et al., ANALYSIS OF PMLSM USING 3-DIMENSIONAL EQUIVALENT MAGNETIC-CIRCUIT NETWORK METHOD, IEEE transactions on magnetics, 33(5), 1997, pp. 4143-4145
Citations number
3
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
00189464
Volume
33
Issue
5
Year of publication
1997
Part
2
Pages
4143 - 4145
Database
ISI
SICI code
0018-9464(1997)33:5<4143:AOPU3E>2.0.ZU;2-3
Abstract
This paper presents characteristics of a permanent magnet linear synch ronous motor (PMLSM) considering lateral leakage flux and lateral disp lacement, In order to analyze the PMLSM with large air gap and finite width, A new three dimensional equivalent magnetic circuit network met hod (3D EMC) is introduced, which supplements the magnetic equivalent circuit by using numerical techniques, It can model flux ripple three- dimensionally by the teeth and slot structure of the PMLSM, and can ta ke nonlinear magnetic phenomenon into account, which results from usin g the distributed magnetic circuit parameter, permeance, The analysis considering lateral flux and lateral displacement in the PMLSM which i s problematic in 3D is performed using 3D EMC and is compared with the experimental value.