RAPID METHOD FOR THE DETERMINATION OF PIROXICAM IN RAT PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

Citation
M. Amanlou et Ar. Dehpour, RAPID METHOD FOR THE DETERMINATION OF PIROXICAM IN RAT PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, Journal of chromatography B. Biomedical sciences and applications, 696(2), 1997, pp. 317-319
Citations number
8
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
ISSN journal
13872273
Volume
696
Issue
2
Year of publication
1997
Pages
317 - 319
Database
ISI
SICI code
0378-4347(1997)696:2<317:RMFTDO>2.0.ZU;2-O
Abstract
A previously published method was used for the determination of piroxi cam in plasma samples obtained from rat. The sample preparation involv ed liquid extraction, centrifugation and evaporation. Separation of pi roxicam from internal standard occurred on a reversed-phase C-18 colum n with a mobile phase consisting of methanol-phosphate buffer pH 2 (45 :55). The detection limit of the assay was 0.02-20 mu g/ml. The assay linearity was good (typically r=0.9992). The method was applied for de termination of piroxicam in rats after administration of an oral dose of 2 mg/kg piroxicam. (C) 1997 Elsevier Science B.V.