Citation: Wh. Finlay et Kw. Stapleton, UNDERSIZING OF DROPLETS FROM A VENTED NEBULIZER CAUSED BY AEROSOL HEATING DURING TRANSIT THROUGH AN ANDERSON IMPACTOR, Journal of aerosol science, 30(1), 1999, pp. 105-109
Citation: Wh. Finlay et al., VARIATIONS IN PREDICTED REGIONAL LUNG DEPOSITION OF SALBUTAMOL SULFATE BETWEEN 19 NEBULIZER TYPES, Journal of aerosol medicine, 11(2), 1998, pp. 65-80
Citation: Wh. Finlay et al., COMPARISONS BETWEEN INHALED FINE-PARTICLE FRACTIONS AND LUNG DOSE FORNEBULIZED AEROSOLS, Journal of aerosol medicine, 11, 1998, pp. 65-72
Citation: Kw. Stapleton et Wh. Finlay, ERRORS IN CHARACTERIZING NEBULIZED PARTICLE-SIZE DISTRIBUTIONS WITH CASCADE IMPACTORS, Journal of aerosol medicine, 11, 1998, pp. 80-83
Citation: Wh. Finlay, INERTIAL SIZING OF AEROSOL INHALED DURING PEDIATRIC TIDAL BREATHING FROM AN MDI WITH ATTACHED HOLDING CHAMBER, International journal of pharmaceutics, 168(2), 1998, pp. 147-152
Citation: Wh. Finlay et Jp. Wong, REGIONAL LUNG DEPOSITION OF NEBULIZED LIPOSOME-ENCAPSULATED CIPROFLOXACIN, International journal of pharmaceutics, 167(1-2), 1998, pp. 121-127
Citation: Wh. Finlay et al., PARTICLE-SIZE MEASUREMENTS FOR THE SPACE-CHAMBER METERED-DOSE INHALERHOLDING CHAMBER COMPARED WITH AEROCHAMBER AND METERED-DOSE INHALER ALONE, Journal of aerosol medicine, 10(3), 1997, pp. 213-219
Citation: Wh. Finlay et al., ERRORS IN REGIONAL LUNG DEPOSITION PREDICTIONS OF NEBULIZED SALBUTAMOL SULFATE DUE TO NEGLECT OR PARTIAL INCLUSION OF HYGROSCOPIC EFFECTS, International journal of pharmaceutics, 149(1), 1997, pp. 63-72
Citation: Wh. Finlay et al., PREDICTING REGIONAL LUNG DOSAGES OF A NEBULIZED SUSPENSION - PULMICORT(R) (BUDESONIDE), Particulate science and technology, 15(3-4), 1997, pp. 243-251
Citation: Wh. Finlay et al., PREDICTING REGIONAL LUNG DOSAGES OF A NEBULIZED SUSPENSION - PULMICORT(R) (BUDESONIDE), Particulate science and technology, 15(3), 1997, pp. 185-193
Citation: Wh. Finlay et al., FINE-PARTICLE FRACTION AS A MEASURE OF MASS DEPOSITING IN THE LUNG DURING INHALATION OF NEARLY ISOTONIC NEBULIZED AEROSOLS, Journal of aerosol science, 28(7), 1997, pp. 1301-1309
Authors:
FINLAY WH
STAPLETON KW
CHAN HK
ZUBERBUHLER P
GONDA I
Citation: Wh. Finlay et al., REGIONAL DEPOSITION OF INHALED HYGROSCOPIC AEROSOLS - IN-VIVO SPECT COMPARED WITH MATHEMATICAL-MODELING, Journal of applied physiology, 81(1), 1996, pp. 374-383
Citation: Wh. Finlay et al., ON THE USE OF COMPUTATIONAL FLUID-DYNAMICS FOR SIMULATING FLOW AND PARTICLE DEPOSITION IN THE HUMAN RESPIRATORY-TRACT, Journal of aerosol medicine, 9(3), 1996, pp. 329-341
Citation: Hb. Chen et al., 3-DIMENSIONAL VISCOUS-FLOW THROUGH A ROTATING CHANNEL - A PSEUDOSPECTRAL MATRIX-METHOD APPROACH, International journal for numerical methods in fluids, 23(4), 1996, pp. 379-396
Authors:
PROKOP RM
FINLAY WH
STAPLETON KW
ZUBERBUHLER P
Citation: Rm. Prokop et al., THE EFFECT OF AMBIENT RELATIVE-HUMIDITY ON REGIONAL DOSAGES DELIVEREDBY A JET NEBULIZER, Journal of aerosol medicine, 8(4), 1995, pp. 363-372
Citation: Rm. Prokop et al., THE DEVELOPMENT AND LINEAR-STABILITY OF ROTATING BOUNDARY-LAYERS, Transactions of the Canadian Society for Mechanical Engineering, 19(4), 1995, pp. 471-487
Citation: Rm. Prokop et al., AN IN-VITRO TECHNIQUE FOR CALCULATING THE REGIONAL DOSAGES OF DRUGS DELIVERED BY AN ULTRASONIC NEBULIZER, Journal of aerosol science, 26(5), 1995, pp. 847-860
Citation: Wh. Finlay et Kw. Stapleton, THE EFFECT ON REGIONAL LUNG DEPOSITION OF COUPLED HEAT AND MASS-TRANSFER BETWEEN HYGROSCOPIC DROPLETS AND THEIR SURROUNDING PHASE, Journal of aerosol science, 26(4), 1995, pp. 655-670
Citation: Kw. Stapleton et Wh. Finlay, DETERMINING SOLUTION CONCENTRATION WITHIN AEROSOL DROPLETS OUTPUT BY JET NEBULIZERS, Journal of aerosol science, 26(1), 1995, pp. 137-145
Citation: Kw. Stapleton et al., AN IN-VITRO METHOD FOR DETERMINING REGIONAL DOSAGES DELIVERED BY JET NEBULIZERS, Journal of aerosol medicine, 7(4), 1994, pp. 325-344
Citation: Y. Guo et Wh. Finlay, WAVE-NUMBER SELECTION AND IRREGULARITY OF SPATIALLY DEVELOPING NONLINEAR DEAN AND GORTLER VORTICES, Journal of Fluid Mechanics, 264, 1994, pp. 1-40
Citation: Wh. Finlay et al., INFERRING SECONDARY FLOWS FROM SMOKE OR DYE FLOW VISUALIZATION - 2 CASE-STUDIES, Physics of fluids. A, Fluid dynamics, 5(11), 1993, pp. 2689-2701