AAAAAA

   
Results: 1-16 |
Results: 16

Authors: Heise, HM Muller, U Gartner, AG Holscher, N
Citation: Hm. Heise et al., Improved chemometric strategies for quantitative FTIR spectral analysis and applications in atmospheric open-path monitoring, FIELD A C T, 5(1-2), 2001, pp. 13-28

Authors: Muller, U Heise, HM
Citation: U. Muller et Hm. Heise, Reliable component identification in atmospheric open-path FTIR spectroscopy by a cross-correlation method, FIELD A C T, 5(1-2), 2001, pp. 50-59

Authors: Heise, HM Kupper, L Pittermann, W Butvina, LN
Citation: Hm. Heise et al., New tool for epidermal and cosmetic formulation studies by attenuated total-reflection spectroscopy using a flexible mid-infrared fiber probe, FRESEN J AN, 371(6), 2001, pp. 753-757

Authors: Kupper, L Heise, HM Bechara, FG Stucker, M
Citation: L. Kupper et al., Micro-domain analysis of skin samples of moor-mummified corpses by evanescent wave infrared spectroscopy using silver halide fibers, J MOL STRUC, 565, 2001, pp. 497-504

Authors: Kurte, R Heise, HM Klockow, D
Citation: R. Kurte et al., Quantitative infrared spectroscopic analysis of SF6 decomposition productsobtained by electrical partial discharges and sparks using PLS-calibrations, J MOL STRUC, 565, 2001, pp. 505-513

Authors: Kupper, L Heise, HM Butvina, LN
Citation: L. Kupper et al., Novel developments in mid-IR fiber-optic spectroscopy for analytical applications, J MOL STRUC, 563, 2001, pp. 173-181

Authors: Kupper, L Heise, HM Lampen, P Davies, AN McIntyre, P
Citation: L. Kupper et al., Authentication and quantification of extra virgin olive oils by attenuatedtotal reflectance infrared spectroscopy using silver halide fiber probes and partial least-squares calibration, APPL SPECTR, 55(5), 2001, pp. 563-570

Authors: Heise, HM Voigt, G Lampen, P Kupper, L Rudloff, S Werner, G
Citation: Hm. Heise et al., Multivariate calibration for the determination of analytes in urine using mid-infrared attenuated total reflection spectroscopy, APPL SPECTR, 55(4), 2001, pp. 434-443

Authors: Heise, HM
Citation: Hm. Heise, Clinical applications of near- and mid-infrared spectroscopy, PRAC SPECTR, 24, 2001, pp. 259-322

Authors: Heise, HM Bittner, A Marbach, R
Citation: Hm. Heise et al., Near-infrared reflectance spectroscopy for noninvasive monitoring of metabolites, CLIN CH L M, 38(2), 2000, pp. 137-145

Authors: Heise, HM Lampen, P
Citation: Hm. Heise et P. Lampen, Transcutaneous glucose measurements using near-infrared spectroscopy, DIABET CARE, 23(8), 2000, pp. 1208-1209

Authors: Muller, U Heise, HM Mosebach, H Gartner, AG Hausler, T
Citation: U. Muller et al., Improved strategies for quantitative evaluation of atmospheric FTIR spectra obtained in open-path monitoring, FIELD A C T, 3(3), 1999, pp. 141-159

Authors: Muller, U Kurte, R Heise, HM
Citation: U. Muller et al., Investigation of photometric errors in FTIR-spectra obtained in open-path monitoring, J MOL STRUC, 483, 1999, pp. 539-544

Authors: Kurte, R Heise, HM Klockow, D
Citation: R. Kurte et al., Analysis of spark decomposition products of SF6 using multivariate mid-infrared spectrum evaluation, J MOL STRUC, 481, 1999, pp. 211-217

Authors: Heise, HM Kupper, L Butvina, LN
Citation: Hm. Heise et al., Attenuated total reflection mid-infrared spectroscopy for clinical chemistry applications using silver halide fibers, SENS ACTU-B, 51(1-3), 1998, pp. 84-91

Authors: Hoffmann, J Lubbers, DW Heise, HM
Citation: J. Hoffmann et al., Applicability of the Kubelka-Munk theory for the evaluation of reflectancespectra demonstrated for haemoglobin-free perfused heart tissue, PHYS MED BI, 43(12), 1998, pp. 3571-3587
Risultati: 1-16 |