AAAAAA

   
Results: 1-13 |
Results: 13

Authors: Kurita, R Tabei, H Hayashi, K Horiuchi, T Torimitsu, K Niwa, O
Citation: R. Kurita et al., Improvement in signal reliability when measuring L-glutamate released fromcultured cells using multi-channel microfabricated sensors, ANALYT CHIM, 441(2), 2001, pp. 165-174

Authors: Liu, ZM Niwa, O Kurita, R Horiuchi, T
Citation: Zm. Liu et al., Miniaturized thin-layer radial flow cell with interdigitated ring-shaped microarray electrode used as amperometric detector for capillary electrophoresis, J CHROMAT A, 891(1), 2000, pp. 149-156

Authors: Niwa, O Horiuchi, T Kurita, R Torimitsu, K
Citation: O. Niwa et al., Electroanalytical chemistry for micro total analysis system (2) - 1. Application of microfabricated biosensor chip for neuroscience, ELECTROCH, 68(4), 2000, pp. 284-288

Authors: Teranishi, T Kurita, R Miyake, M
Citation: T. Teranishi et al., Shape control of Pt nanoparticles, J INORG ORG, 10(3), 2000, pp. 145-156

Authors: Hayashi, K Horiuchi, T Kurita, R Torimitsu, K Niwa, O
Citation: K. Hayashi et al., Real-time electrochemical imaging using an individually addressable multi-channel electrode, BIOSENS BIO, 15(9-10), 2000, pp. 523-529

Authors: Kurita, R Tabei, H Liu, ZM Horiuchi, T Niwa, O
Citation: R. Kurita et al., Fabrication and electrochemical properties of an interdigitated array electrode in a microfabricated wall-jet cell, SENS ACTU-B, 71(1-2), 2000, pp. 82-89

Authors: Niwa, O Kurita, R Hayashi, K Horiuchi, T Torimitsu, K Maeyama, K Tanizawa, K
Citation: O. Niwa et al., Continuous measurement of histamine from rat basophilic leukemia cells (RBL-2H3) with an on-line sensor using histamine oxidase, SENS ACTU-B, 67(1-2), 2000, pp. 43-51

Authors: Kurita, R Koyano, M Katayama, S
Citation: R. Kurita et al., Field modulation effects on charge-density-wave conduction in NbSe3, PHYSICA B, 284, 2000, pp. 1661-1662

Authors: Kurita, R
Citation: R. Kurita, Current modulation of charge-density-wave field-effect transistors with NbSe3 channel, J PHYS JPN, 69(8), 2000, pp. 2604-2608

Authors: Liu, ZM Niwa, O Kurita, R Horiuchi, T
Citation: Zm. Liu et al., Carbon film-based interdigitated array microelectrode used in capillary electrophoresis with electrochemical detection, ANALYT CHEM, 72(6), 2000, pp. 1315-1321

Authors: Niwa, O Kurita, R Liu, ZM Horiuchi, T Torimitsue, K
Citation: O. Niwa et al., Subnanoliter volume wall-jet cells combined with interdigitated microarrayelectrode and enzyme modified planar microelectrode, ANALYT CHEM, 72(5), 2000, pp. 949-955

Authors: Niwa, O Kurita, R Horiuchi, T Torimitsu, K
Citation: O. Niwa et al., Continuous monitoring of L-glutamate released from cultured rat nerve cells with a microfabricated on-line sensor at a slow flow rate, ELECTROANAL, 11(5), 1999, pp. 356-361

Authors: Liu, ZM Niwa, O Horiuchi, T Kurita, R Torimitsu, K
Citation: Zm. Liu et al., NADH and glutamate on-line sensors using Os-gel-HRP/GC electrodes modifiedwith NADH oxidase and glutamate dehydrogenase, BIOSENS BIO, 14(7), 1999, pp. 631-638
Risultati: 1-13 |