Citation: Ql. Mao et al., Dynamics of capillary isoelectric focusing in the absence of fluid flow: High resolution computer simulation and experimental validation with whole column optical imaging, ANALYT CHEM, 72(21), 2000, pp. 5493-5502
Citation: B. Shurmer et J. Pawliszyn, Determination of distribution constants between a liquid polymeric coatingand water by a solid phase microextraction technique with a flow-through standard water system, ANALYT CHEM, 72(15), 2000, pp. 3660-3664
Citation: Yn. Gou et J. Pawliszyn, In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples, ANALYT CHEM, 72(13), 2000, pp. 2774-2779
Citation: Jc. Wu et al., Speciation of organoarsenic compounds by polypyrrole-coated capillary in-tube solid phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry, ANALYT CHIM, 424(2), 2000, pp. 211-222
Citation: Tm. Huang et J. Pawliszyn, Axially illuminated fluorescence imaging detection for capillary isoelectric focusing on Teflon capillary, ANALYST, 125(7), 2000, pp. 1231-1233
Citation: Jc. Wu et al., Automated in-tube solid phase microextraction coupled with HPLC-ES-MS for the determination of catechins and caffeine in tea, ANALYST, 125(12), 2000, pp. 2216-2222
Citation: H. Kataoka et al., Automated in-tube solid-phase microextraction-liquid chromatography-electrospray ionization mass spectrometry for the determination of ranitidine, J CHROMAT B, 731(2), 1999, pp. 353-359
Citation: Ql. Mao et J. Pawliszyn, Effect of salt concentration on separation patterns in static capillary isoelectric focusing with imaging detection, J CHROMAT B, 729(1-2), 1999, pp. 355-359
Citation: Z. Mester et J. Pawliszyn, Electrospray mass spectrometry of trimethyllead and triethyllead with in-tube solid phase microextraction sample introduction, RAP C MASS, 13(20), 1999, pp. 1999-2003
Citation: A. Moder et al., Determination of polar pesticides in soil by solid phase microextraction coupled to high-performance liquid chromatography-electrospray mass spectrometry, FRESEN J AN, 363(7), 1999, pp. 680-685
Citation: Ql. Mao et J. Pawliszyn, Capillary isoelectric focusing with whole column imaging detection for analysis of proteins and peptides, J BIOCH BIO, 39(1-2), 1999, pp. 93-110
Citation: H. Kataoka et J. Pawliszyn, Development of in-tube solid-phase microextraction/liquid chromatography/electrospray ionization mass spectrometry for the analysis of mutagenic heterocyclic amines, CHROMATOGR, 50(9-10), 1999, pp. 532-538
Citation: Pa. Martos et J. Pawliszyn, Time-weighted average sampling with solid-phase microextraction devise: Implications for enhanced personal exposure monitoring to airborne pollutants, ANALYT CHEM, 71(8), 1999, pp. 1513-1520
Authors:
Kataoka', H
Narimatsu, S
Lord, HL
Pawliszyn, J
Citation: H. Kataoka' et al., Automated in tube solid-phase microextraction coupled with liquid chromatography/electrospray ionization mass spectrometry for the determination of beta-blockers and metabolites in urine and serum samples, ANALYT CHEM, 71(19), 1999, pp. 4237-4244
Citation: Jq. Wu et al., Capillary isoelectric focusing with whole column detection and a membrane sample preparation system, ANALYT CHIM, 383(1-2), 1999, pp. 67-78
Citation: Ql. Mao et J. Pawliszyn, Demonstration of isoelectric focusing on an etched quartz chip with UV absorption imaging detection, ANALYST, 124(5), 1999, pp. 637-641