T. Bergann et J. Langanke, MODEL EXPERIMENTS TO DETECTION OF ABSCESS ES WITH ULTRA SONOGRAPHY INCARCASSES OF PIGS, Die Fleischwirtschaft, 76(2), 1996, pp. 130-131
In primary abscessfree muscular tissue the detection of model abscesse
s was tested with ultrasonography. With water, agar or plaster filled
rubber balls simulated abscesses with different dimensions and consist
encies. With Linearscanners (5.0 and 7.5 MHz) the detection of models,
which a minimum of 0,5 cm in diameter and a maximum of 7 cm in depth,
was succeeded. Here the shadow and intensification of sound behind th
e abscess appears to be important for the good description of model ab
scesses. The ultrasonographical inspection with portable apparatuses c
ould be a method of detecting of hidden defects in the meat.