Ts. Kahlon et al., QUANTITATIVE EXTRACTION OF HAMSTER LIVER LIPID AND CHOLESTEROL WITH SUPERCRITICAL CARBON-DIOXIDE, Journal of the American Oil Chemists' Society, 73(10), 1996, pp. 1341-1342
A quantitative method for liver lipid and cholesterol extraction with
supercritical CO2 and ethanol entrainer (SCE) is reported and compared
with the Folch (chloroform/methanol) procedure. Mean values for lipid
and cholesterol in hamster livers (n=48) were similar between the SCE
and Folch methods. Correlation coefficients between the two methods w
ere 0.9866 for total lipid and 0.9546 for cholesterol. Similar mean va
lues and high correlations between the two methods validate the SCE pr
ocedure as a precise alternative method ior quantitative liver lipid e
xtractions. The SCE method also reduces the use of hazardous solvents.