A COMPLEX 2-UNIT SYSTEM WITH RANDOM BREAKDOWN OF REPAIR FACILITY

Citation
M. Gururajan et B. Srinivasan, A COMPLEX 2-UNIT SYSTEM WITH RANDOM BREAKDOWN OF REPAIR FACILITY, Microelectronics and reliability, 35(2), 1995, pp. 299-302
Citations number
4
Categorie Soggetti
Engineering, Eletrical & Electronic
ISSN journal
00262714
Volume
35
Issue
2
Year of publication
1995
Pages
299 - 302
Database
ISI
SICI code
0026-2714(1995)35:2<299:AC2SWR>2.0.ZU;2-7
Abstract
This paper deals with a two-unit warm standby system with a single rep air facility. The lifetime of the functioning (online) unit has a gene ral distribution, while the standby unit has a phase-type distribution . The repair facility is subjected to random breakdown and is restored after a random time. The statistical characteristics, such as reliabi lity, availability and interval reliability, are provided for the mode l.