Fi. Buchholz et al., MICROWAVE NOISE POWER - REALIZATION OF TH E UNIT AND TRANSFER BY AN INTERLABORATORY COMPARISON, TM. Technisches Messen, 62(2), 1995, pp. 74-81
Within the German Calibration Service (DKD) the first interlaboratory
comparison of microwave noise power took place in a national loop betw
een the PTB and several calibration laboratories. The use of a new tra
nsfer noise standard enabled the broadband link of the reference stand
ards of the participants to the PTB primary noise standards over three
different frequency bands, for the first time. By means of the achiev
ed low measurement uncertainties the quality of measurements is judged
on a uniform basis. AN overview on the state of the art of precision
microwave noise power measuring techniques is given by presenting the
action and the outcome of the comparison.