RELIABILITY OF PASSIVATED COPPER MULTICHIP-MODULE STRUCTURES EMBEDDEDIN POLYIMIDE

Citation
Jm. Cech et al., RELIABILITY OF PASSIVATED COPPER MULTICHIP-MODULE STRUCTURES EMBEDDEDIN POLYIMIDE, IEEE transactions on components, hybrids, and manufacturing technology, 16(7), 1993, pp. 752-758
Citations number
27
Categorie Soggetti
Material Science","Engineering, Eletrical & Electronic
ISSN journal
01486411
Volume
16
Issue
7
Year of publication
1993
Pages
752 - 758
Database
ISI
SICI code
0148-6411(1993)16:7<752:ROPCMS>2.0.ZU;2-Q
Abstract
Multichip module (MCM) structures were used to study the reliability o f copper conductor embedded in polyimide. Conductor lines fully encase d in titanium passivation, 50-100 nm thick, increased in resistance le ss than 0.4% after 1000 h of exposure to 85% humidity at 85-degrees-C and 10-V bias. The fully encased lines also had corrosion rates six ti mes lower than lines that had only 60% passivation coverage. Transmiss ion lines passivated with 50 nm of titanium showed very little degrada tion in the rise time or amplitude of digital pulses that had a 0.5-GH z clock rate and 149-ps rise time. Copper/polyimide via chain structur es were fabricated from vias having dimensions of 10-25 mum. After 100 0 cycles of thermal shock from -65 to 150-degrees-C, via chains showed no significant resistance change.