Clm. Silva et al., EXPERIMENTAL VALIDATION OF MODELS FOR PREDICTING OPTIMAL SURFACE QUALITY STERILIZATION TEMPERATURES, International journal of food science & technology, 29(3), 1994, pp. 227-241
An experimental procedure was developed to validate experimentally the
theoretical optimal process temperatures giving the maximum quality a
t the surface of conduction heating products for specified levels of s
terility. The method involved filling a can with a 10% bentonite solut
ion, placing glass capillaries containing a food quality indicator at
the surface, and processing it at different temperatures for the neces
sary time in order to attain a specified sterility value at the least-
lethality point. The acid catalysed sucrose hydrolysis reaction was us
ed as a chemical time-temperature-integrator for a quality index of he
at sterilized products. At a pH of 3.8, the kinetic parameters D-121.1
5 degrees C and z values of this reaction, were 214 min and 31 degrees
C, respectively. Final surface retentions of sucrose compared well wi
th theoretically predicted values from simulation modelling. Optimal t
emperatures calculated using either numerical computer optimization or
generalized regression equations were in the range of experimentally
determined optimal conditions.