Sulphur dioxide and sodium, potassium, calcium salts of hydrogen-sulph
ite, disulphite and sulphite ions are extensively used as food additiv
es for their technological efficacy and versatility. They are active a
s antimicrobial agents, enzyme inhibitors, antioxidants, structure mod
ifiers, in the control of enzymatic and nonenzymatic browning reaction
s with stabilising and conditioning functions. In this study a modifie
d Monier-Williams method has been utilised as a preparative procedure
to obtain both the free and bound sulphite fractions. The two fraction
s have been analysed by HPLC with indirect photometric detection using
a 250 x 4.6 mm LC-SAX column eluted with a solution of potassium hydr
ogen phthalate. Levels of 5-10 ppm of SO2 in foods, corresponding to 3
0-60 ng injected are reliably detected by this method. The results con
firm that the chromatographic method, unlike the Monier-Williams metho
d, is able to avoid the potential interference of volatile substances
derived from matrices or utilised chemicals. (C) 1998 Elsevier Science
Ltd. All rights reserved.