Yl. Khong et Hl. Lee, Chemical imaging of micro-vias in organic packages, PROCEEDINGS OF 3RD ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2000, pp. 154-158
Distribution of chemical species in cross sectioned micro-via were observed
using the Time-Of-Flight-Secondary-Ion-Mass-Spectroscopy (TOF-SIMS). The T
OF-SIMS combines high molecular and elemental detection sensitivities and g
ood lateral resolution for detection of molecular and elemental content in
the micro-via and surrounding structures of the flip-chip-pin-grid array pa
ckages (FCPGA) fabricated from several sources. The data obtained indicate
that it is feasible to compare and monitor organic package fabrication proc
esses using TOF-SIMS chemical images.