AAAAAA

   
Results: 1-17 |
Results: 17

Authors: Xu, DF Katsu, T
Citation: Df. Xu et T. Katsu, Application of tri-n-octylphosphine oxide as an ionophore for a vanadyl ion-selective membrane electrode, ELECTROANAL, 13(10), 2001, pp. 868-871

Authors: Katsu, T Matsumoto, M
Citation: T. Katsu et M. Matsumoto, Discrimination of methylammonium from organic ammonium ions using ion-selective electrodes based on calix[4]arene-crown-6 conjugates, ANAL SCI, 17(6), 2001, pp. 721-725

Authors: Katsu, T Ido, K Kataoka, K
Citation: T. Katsu et al., Acyclic neutral carrier-based polymer membrane electrode for a stimulant, phentermine, ANAL SCI, 17(6), 2001, pp. 745-749

Authors: Katsu, T Nakagawa, H Kanamori, T Kamo, N Tsuchiya, T
Citation: T. Katsu et al., Ion-selective electrode for transmembrane pH difference measurements, ANALYT CHEM, 73(8), 2001, pp. 1849-1854

Authors: Xu, DF Katsu, T
Citation: Df. Xu et T. Katsu, O,O,O-trialkyl phosphorothioates as simple and effective ionophores for silver ion-selective membrane electrodes, ANALYT CHIM, 443(2), 2001, pp. 235-240

Authors: Katsu, T Ido, K Moriya, A Nakae, Y Sakata, I
Citation: T. Katsu et al., Valproate-selective membrane electrode based on gallium(III) tetraphenylporphyrin, ELECTROANAL, 12(16), 2000, pp. 1282-1285

Authors: Katsu, T Hirodo, H
Citation: T. Katsu et H. Hirodo, Biogenic amine-sensitive membrane electrodes using the hydrogen bond-forming ability of solvent mediators, ANAL SCI, 16(8), 2000, pp. 789-793

Authors: Katsu, T Nishimura, N
Citation: T. Katsu et N. Nishimura, Organic ammonium ion-selective electrodes using acyclic neutral carriers developed for inorganic cation-selective electrodes, ANAL SCI, 16(5), 2000, pp. 523-525

Authors: Xu, DF Katsu, T
Citation: Df. Xu et T. Katsu, Tetrabenzyl pyrophosphate as a new class of neutral carrier responsive to lead ion, TALANTA, 51(2), 2000, pp. 365-371

Authors: Katsu, T
Citation: T. Katsu, Application of calcein-loaded liposomes for the determination of membrane channel size, BIOL PHAR B, 22(9), 1999, pp. 978-980

Authors: Katsu, T Hashimoto, T Hiramaki, S
Citation: T. Katsu et al., Potentiometric determination of NAD(P)H coenzymes using a nitrite-selective membrane electrode and a nitrate reductase enzyme and the application to glucose assay in human serum, ANAL SCI, 15(2), 1999, pp. 135-139

Authors: Katsu, T Mori, Y Furuno, K Gomita, Y
Citation: T. Katsu et al., Mexiletine-sensitive membrane electrode for medical application, J PHARM B, 19(3-4), 1999, pp. 585-593

Authors: Katsu, T Hashimoto, T
Citation: T. Katsu et T. Hashimoto, Triphenyllead chloride as a new ionophore for an iodide-selective membraneelectrode, ANAL LETTER, 32(4), 1999, pp. 665-675

Authors: Funasaki, N Kawaguchi, R Ishikawa, S Hada, S Neya, S Katsu, T
Citation: N. Funasaki et al., Quantitative estimation of the bitter taste intensity of oxyphenonium bromide reduced by cyclodextrins from electromotive force measurements, ANALYT CHEM, 71(9), 1999, pp. 1733-1736

Authors: Xu, DF Katsu, T
Citation: Df. Xu et T. Katsu, Lead-selective membrane electrode based on dibenzyl phosphate, ANALYT CHIM, 401(1-2), 1999, pp. 111-115

Authors: Katsu, T Hirodo, H
Citation: T. Katsu et H. Hirodo, Determination of histamine release from mast cells using a histamine-sensitive membrane electrode, ANALYT CHIM, 396(2-3), 1999, pp. 189-193

Authors: Katsu, T Nakashima, K
Citation: T. Katsu et K. Nakashima, Simultaneous determination of changes in the permeability of two differentliposomes mimicking bacterial and eukaryotic cell membranes using ion-selective electrodes, ANALYST, 124(6), 1999, pp. 883-886
Risultati: 1-17 |