Citation: N. Rosarius et al., CONCEPT, REALIZATION, AND 1ST IN-VITRO TESTING OF AN INTRAARTERIAL MICROAXIAL BLOOD PUMP WITH AN INTEGRATED DRIVE UNIT, Artificial organs, 18(7), 1994, pp. 512-516
Authors:
FASS J
SILNY J
BRAUN J
HEINDRICHS U
DREUW B
SCHUMPELICK V
RAU G
Citation: J. Fass et al., MEASURING ESOPHAGEAL MOTILITY WITH A NEW INTRALUMINAL IMPEDANCE DEVICE - FIRST CLINICAL-RESULTS IN REFLUX PATIENTS, Scandinavian journal of gastroenterology, 29(8), 1994, pp. 693-702
Citation: R. Effert et al., AUTOMATED MEASUREMENT OF VISUAL FAR AND N EAR ACUITY, Klinische Monatsblatter fur Augenheilkunde, 204(3), 1994, pp. 181-183
Authors:
SILNY J
KNIGGE KP
FASS J
RAU G
MATERN S
SCHUMPELICK V
Citation: J. Silny et al., VERIFICATION OF THE INTRALUMINAL MULTIPLE ELECTRICAL-IMPEDANCE MEASUREMENT FOR THE RECORDING OF GASTROINTESTINAL MOTILITY, Journal of gastrointestinal motility, 5(2), 1993, pp. 107-122
Citation: B. Thull et al., MAN-MACHINE INTERACTION IN CRITICAL CARE SETTINGS, IEEE engineering in medicine and biology magazine, 12(4), 1993, pp. 42-49
Authors:
KINGSBURY C
KAFESJIAN R
GUO G
ADLPARVAR P
UNGER J
QUIJANO RC
GRAF T
FISHER H
REUL H
RAU G
Citation: C. Kingsbury et al., CAVITATION THRESHOLD WITH RESPECT TO DP DT - EVALUATION IN 29 MM BILEAFLET, PYROLITIC CARBON HEART-VALVES/, International journal of artificial organs, 16(7), 1993, pp. 515-520
Authors:
RAMAEKERS VT
DISSELHORSTKLUG C
SCHNEIDER J
SILNY J
FORST J
FORST R
KOTLAREK F
RAU G
Citation: Vt. Ramaekers et al., CLINICAL-APPLICATION OF A NONINVASIVE MULTIELECTRODE ARRAY EMG FOR THE RECORDING OF SINGLE MOTOR UNIT-ACTIVITY, Neuropediatrics, 24(3), 1993, pp. 134-138
Citation: Vt. Ramaekers et al., RECOVERY FROM NEUROLOGICAL DEFICITS FOLLOWING BIOTIN TREATMENT IN A BIOTINIDASE KM VARIANT, Neuropediatrics, 24(2), 1993, pp. 98-102
Authors:
REUL H
VANSON JAM
STEINSEIFER U
SCHMITZ B
SCHMIDT A
SCHMITZ C
RAU G
Citation: H. Reul et al., IN-VITRO COMPARISON OF BILEAFLET AORTIC HEART-VALVE PROSTHESES - ST-JUDE MEDICAL, CARBOMEDICS, MODIFIED EDWARDS-DUROMEDICS, AND SORIN-BICARBON VALVES, Journal of thoracic and cardiovascular surgery, 106(3), 1993, pp. 412-420
Authors:
NGUYEN HN
SILNY J
KNIGGE KP
RAU G
MATERN S
Citation: Hn. Nguyen et al., INTRALUMINAL ELECTRIC IMPEDANCE MEASUREMENT AS A TECHNICAL APPROACH FOR INVESTIGATION OF INTESTINAL MOTILITY, Gastroenterology, 104(4), 1993, pp. 559-559
Citation: G. Rau, APPLICATION OF CARBON-DIOXIDE FOR THE STO RAGE OF FOODSTUFFS AND MEDICINAL-PLANTS, Deutsche Lebensmittel-Rundschau, 89(7), 1993, pp. 216-219