Authors:
Lehmann, C
Wollenberger, U
Brigelius-Flohe, R
Scheller, FW
Citation: C. Lehmann et al., Modified gold electrodes for electrochemical studies of the reaction of phospholipid hydroperoxide glutathione peroxidase with glutathione and glutathione disulfide, ELECTROANAL, 13(5), 2001, pp. 364-369
Authors:
Rose, A
Scheller, FW
Wollenberger, U
Pfeiffer, D
Citation: A. Rose et al., Quinoprotein glucose dehydrogenase modified thick-film electrodes for the amperometric detection of phenolic compounds in flow injection analysis, FRESEN J AN, 369(2), 2001, pp. 145-152
Authors:
Lisdat, F
Utepbergenov, D
Haseloff, RF
Blasig, IE
Stocklein, W
Scheller, FW
Brigelius-Flohe, R
Citation: F. Lisdat et al., An optical method for the detection of oxidative stress using protein-RNA interaction, ANALYT CHEM, 73(5), 2001, pp. 957-962
Authors:
Streffer, K
Vijgenboom, E
Tepper, AWJW
Makower, A
Scheller, FW
Canters, GW
Wollenberger, U
Citation: K. Streffer et al., Determination of phenolic compounds using recombinant tyrosinase from Streptomyces antibioticus, ANALYT CHIM, 427(2), 2001, pp. 201-210
Authors:
Benkert, A
Scheller, FW
Schoessler, W
Micheel, B
Warsinke, A
Citation: A. Benkert et al., Size exclusion redox-labeled immunoassay (SERI): a new format for homogeneous amperometric creatinine determination, ELECTROANAL, 12(16), 2000, pp. 1318-1321
Authors:
Lisdat, F
Ge, B
Stocklein, W
Scheller, FW
Meyer, T
Citation: F. Lisdat et al., Electrochemical behavior and nitric oxide interaction of immobilized cytochrome c ' from Rhodocyclus gelatinosus, ELECTROANAL, 12(12), 2000, pp. 946-951
Authors:
Stocklein, WFM
Behrsing, O
Scharte, G
Micheel, B
Benkert, A
Schossler, W
Warsinke, A
Scheller, FW
Citation: Wfm. Stocklein et al., Enzyme kinetic assays with surface plasmon resonance (BIAcore) based on competition between enzyme and creatinine antibody, BIOSENS BIO, 15(7-8), 2000, pp. 377-382
Authors:
Fridman, V
Wollenberger, U
Bogdanovskaya, V
Lisdat, F
Ruzgas, T
Lindgren, A
Gorton, L
Scheller, FW
Citation: V. Fridman et al., Electrochemical investigation of cellobiose oxidation by cellobiose dehydrogenase in the presence of cytochrome c as mediator, BIOCH SOC T, 28, 2000, pp. 63-70
Authors:
Chen, ZQ
Warsinke, A
Gajovic, N
Grosse, S
Hu, J
Kleber, HP
Scheller, FW
Citation: Zq. Chen et al., A D-carnitine dehydrogenase electrode for the assessment of enantiomeric purity of L-carnitine preparations, ANAL LETTER, 33(6), 2000, pp. 1079-1089
Authors:
Gajovic, N
Binyamin, G
Warsinke, A
Scheller, FW
Heller, A
Citation: N. Gajovic et al., Operation of a miniature redox hydrogel-based pyruvate sensor in undiluteddeoxygenated calf serum, ANALYT CHEM, 72(13), 2000, pp. 2963-2968
Authors:
Stocklein, WFM
Rohde, M
Scharte, G
Behrsing, O
Warsinke, A
Micheel, B
Scheller, FW
Citation: Wfm. Stocklein et al., Sensitive detection of triazine and phenylurea pesticides in pure organic solvent by enzyme linked immunosorbent assay (ELISA): stabilities, solubilities and sensitivities, ANALYT CHIM, 405(1-2), 2000, pp. 255-265
Authors:
Huang, T
Warsinke, A
Koroljova-Skovobogat'ko, OV
Makower, A
Kuwana, T
Scheller, FW
Citation: T. Huang et al., A bienzyme carbon paste electrode for the sensitive detection of NADPH andthe measurement of glucose-6-phosphate dehydrogenase, ELECTROANAL, 11(5), 1999, pp. 295-300
Authors:
Gajovic, N
Habermuller, K
Warsinke, A
Schuhmann, W
Scheller, FW
Citation: N. Gajovic et al., A pyruvate oxidase electrode based on an electrochemically deposited redoxpolymer, ELECTROANAL, 11(18), 1999, pp. 1377-1383