Citation: K. Polgar et al., A comparison between automatically generated linear and parabolic tetrahedra when used to mesh a human femur, P I MEC E H, 215(H1), 2001, pp. 85-94
Authors:
Viceconti, M
Monti, L
Muccini, R
Bernakiewicz, M
Toni, A
Citation: M. Viceconti et al., Even a thin layer of soft tissue may compromise the primary stability of cementless hip stems, CLIN BIOMEC, 16(9), 2001, pp. 765-775
Authors:
Viceconti, M
Cristofolini, L
Baleani, M
Toni, A
Citation: M. Viceconti et al., Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods, J BIOMECHAN, 34(6), 2001, pp. 723-731
Citation: L. Cristofolini et M. Viceconti, Comments on "Femoral surface strain in intact composite femurs: A custom computer analysis of the photoelastic coating technique", IEEE BIOMED, 48(8), 2001, pp. 944-945
Citation: M. Viceconti et al., Development of a software for the design of custom-made hip prostheses using an open-source rapid application development environment, MED INF IN, 25(3), 2000, pp. 183-193
Authors:
Cristofolini, L
Marchetti, A
Cappello, A
Viceconti, M
Citation: L. Cristofolini et al., A novel transducer for the measurement of cement-prosthesis interface forces in cemented orthopaedic devices, MED ENG PHY, 22(7), 2000, pp. 493-501
Citation: M. Viceconti, A comparative study on different methods of automatic mesh generation of human femurs - Medical Engineering & Physics 20 (1998): 1-10, MED ENG PHY, 22(5), 2000, pp. 379-380
Citation: L. Cristofolini et M. Viceconti, Development and validation of a technique for strain measurement inside polymethyl methacrylate, J STRAIN A, 35(1), 2000, pp. 21-33
Citation: R. Muccini et al., Selection of the best element type in the finite element analysis of hip prostheses, J MED EN TE, 24(4), 2000, pp. 145-148
Citation: M. Baleani et al., The effect of sandblasting treatment on endurance properties of titanium alloy hip prostheses, ARTIF ORGAN, 24(4), 2000, pp. 296-299
Authors:
Viceconti, M
Muccini, R
Bernakiewicz, M
Baleani, M
Cristofolini, L
Citation: M. Viceconti et al., Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration, J BIOMECHAN, 33(12), 2000, pp. 1611-1618
Citation: L. Cristofolini et M. Viceconti, In vitro stress shielding measurements can be affected by large errors, J ARTHROPLA, 14(2), 1999, pp. 215-219
Citation: L. Cristofolini et M. Viceconti, Towards the standardization of in vitro load transfer investigations of hip prostheses, J STRAIN A, 34(1), 1999, pp. 1-15
Citation: M. Baleani et al., Endurance testing of hip prostheses: a comparison between the load fixed in ISO 7206 standard and the physiological loads, CLIN BIOMEC, 14(5), 1999, pp. 339-345
Authors:
Testi, D
Viceconti, M
Baruffaldi, F
Cappello, A
Citation: D. Testi et al., Risk of fracture in elderly patients: a new predictive index based on bonemineral density and finite element analysis, COMPUT M PR, 60(1), 1999, pp. 23-33
Authors:
Viceconti, M
Zannoni, C
Pierotti, L
Casali, M
Citation: M. Viceconti et al., Spatial positioning of an hip stem solid model within the CT data set of the host bone (vol 58, pg 219, 1999), COMPUT M PR, 59(2), 1999, pp. 143-144
Authors:
Viceconti, M
Zannoni, C
Pierotti, L
Casali, M
Citation: M. Viceconti et al., Spatial positioning of an hip stem solid model within the CT data set of the host bone, COMPUT M PR, 58(3), 1999, pp. 219-226