The automation of mash and wort production processes is primarily stil
l based today on time conducted sequence control systems. Process-cond
ucted quality controls can be implemented through the availability of
selective in- or on-line working concentration measuring methods. The
possibility of using of biosensors, process proximative HPLC and NIR s
pectroscopy are covered in the following contribution. By varying the
working parameters and progressive evaluation methods the time require
d for HPLC determination of fermentable sugar can be reduced to appl-o
x. 3 minutes. This makes it possible to monitor and control the runnin
g mashing process. The use of optic-intrinsic NIR sensors developed so
lely for this purpose allows yet quicker determination of the concentr
ation and makes in-line measurement possible without any preparation o
f samples.