AAAAAA

   
Results: 1-15 |
Results: 15

Authors: Tang, H Beebe, DJ Kramer, AF
Citation: H. Tang et al., A multilevel input system with force-sensitive elements, INT J HUM-C, 54(4), 2001, pp. 495-507

Authors: Moorthy, J Khoury, C Moore, JS Beebe, DJ
Citation: J. Moorthy et al., Active control of electroosmotic flow in microchannels using light, SENS ACTU-B, 75(3), 2001, pp. 223-229

Authors: Zhao, B Moore, JS Beebe, DJ
Citation: B. Zhao et al., Surface-directed liquid flow inside microchannels, SCIENCE, 291(5506), 2001, pp. 1023-1026

Authors: Glasgow, IK Zeringue, HC Beebe, DJ Choi, SJ Lyman, JT Chan, NG Wheeler, MB
Citation: Ik. Glasgow et al., Handling individual mammalian embryos using microfluidics, IEEE BIOMED, 48(5), 2001, pp. 570-578

Authors: Yu, Q Bauer, JM Moore, JS Beebe, DJ
Citation: Q. Yu et al., Responsive biomimetic hydrogel valve for microfluidics, APPL PHYS L, 78(17), 2001, pp. 2589-2591

Authors: Liu, RH Stremler, MA Sharp, KV Olsen, MG Santiago, JG Adrian, RJ Aref, H Beebe, DJ
Citation: Rh. Liu et al., Passive mixing in a three-dimensional serpentine microchannel, J MICROEL S, 9(2), 2000, pp. 190-197

Authors: Suh, HJ Bharathi, P Beebe, DJ Moore, JS
Citation: Hj. Suh et al., Dendritic material as a dry-release sacrificial layer, J MICROEL S, 9(2), 2000, pp. 198-205

Authors: Jo, BH Van Lerberghe, LM Motsegood, KM Beebe, DJ
Citation: Bh. Jo et al., Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS)elastomer, J MICROEL S, 9(1), 2000, pp. 76-81

Authors: Wang, L Beebe, DJ
Citation: L. Wang et Dj. Beebe, A silicon-based shear force sensor: development and characterization, SENS ACTU-A, 84(1-2), 2000, pp. 33-44

Authors: Beebe, DJ Moore, JS Bauer, JM Yu, Q Liu, RH Devadoss, C Jo, BH
Citation: Dj. Beebe et al., Functional hydrogel structures for autonomous flow control inside microfluidic channels, NATURE, 404(6778), 2000, pp. 588

Authors: Beebe, DJ Moore, JS Yu, Q Liu, RH Kraft, ML Jo, BH Devadoss, C
Citation: Dj. Beebe et al., Microfluidic tectonics: A comprehensive construction platform for microfluidic systems, P NAS US, 97(25), 2000, pp. 13488-13493

Authors: Folch, A Jo, BH Hurtado, O Beebe, DJ Toner, M
Citation: A. Folch et al., Microfabricated elastomeric stencils for micropatterning cell cultures, J BIOMED MR, 52(2), 2000, pp. 346-353

Authors: Trumbull, JD Glasgow, IK Beebe, DJ Magin, RL
Citation: Jd. Trumbull et al., Integrating microfabricated fluidic systems and NMR spectroscopy, IEEE BIOMED, 47(1), 2000, pp. 3-7

Authors: Olsen, MG Bauer, JM Beebe, DJ
Citation: Mg. Olsen et al., Particle imaging technique for measuring the deformation rate of hydrogel microstructures, APPL PHYS L, 76(22), 2000, pp. 3310-3312

Authors: Liu, RH Vasile, MJ Beebe, DJ
Citation: Rh. Liu et al., The fabrication of nonplanar spin-on glass microstructures, J MICROEL S, 8(2), 1999, pp. 146-151
Risultati: 1-15 |